Report Writer - Custom Templates

Report Writer - Custom Templates

When none of the starter templates fits, design your own. This article builds a Preheat and Interpass Temperature Record from a blank page: a few details about the measurement, the acceptance criteria, a table of readings for each weld with a calculated margin, a corrective action section that only appears when a reading is out of limits, and a sign-off. The same steps apply to any form.

If a starter template is close to what you need, it is quicker to copy or adapt it (see the article "Report Writer: adapt a starter template").

To design templates you need Read/Write access to Reports; super users and account administrators always have it. Only super users and account administrators approve templates. Report Writer is available on the Projects, Projects +, Projects ++ and Enterprise plans.

Step 1 - Start a new template

New template

Open "Reports" in the main menu and click "Report Writer".

  1. Click "New template". A blank draft is created and opens in the designer.

Step 2 - The blank template

The blank template

A new template starts with one section and one field, so you can see how a form is built.

  1. The template's details: name, category, report number prefix, description and page (see Step 3);
  2. A section of fields, here "Details";
  3. Its first field, "Reference". Click a field to open and change it;
  4. "Add field" adds a field to this section;
  5. "Section of fields" adds a section of fields at the end of the form;
  6. "Table" adds a table at the end of the form;
  7. The preview shows the form as it will be filled in, and follows every change you make.

Step 3 - Name the template

The template's details

Replace "New template" with the details of your form.

  1. The name, printed in the report's header and shown when a template is chosen for a new report;
  2. The category, here Welding. Categories group the templates in the list;
  3. The prefix of report numbers, here PH-, so reports are numbered PH-0001, PH-0002 and so on in each project;
  4. A short description, shown in the template list;
  5. The page orientation. A wide table prints better in landscape.

Click "Save" at the top of the designer as you go.

Step 4 - Build a section of fields

A section of fields

Rename the Details section's field and add the others with "Add field". Click a field to open it.

  1. The section's title, printed above its fields;
  2. How many fields sit side by side: one, two or three per row;
  3. "Project number" is linked to WeldTrace and filled from the project. A field linked to the project number, project title, customer or contractor fills itself in every report;
  4. A red asterisk marks a required field, here the date of measurement;
  5. The field's type. Here "Measuring method" is a dropdown;
  6. Tick "Required" when the report cannot be submitted without the field;
  7. The width: a field can span one, two or three columns of the section;
  8. For a dropdown, the choices, one per line. A help text can be added under any field.

Other types include text, long text, number, date, checkbox, pass or fail, accept or reject, signature, photos and fixed text. Here "All readings within limits" is a Pass / Fail field, used in Step 7.

Step 5 - Add a table

A table

Click "Table" to add a table section, rename it "Readings" and add a column for each value with "Add column".

  1. The number of rows a new report starts with. More rows can be added while filling it in;
  2. Where the rows come from. "Rows typed in" leaves the rows to the person filling in the report. "Rows from NDE request", "Rows from Pressure test pack" or "Rows from PWHT pack" fills one row per weld of the chosen request or pack. "Rows from Welds for visual inspection" has no pack: welds that are completed and not visually inspected yet are picked on the report, by drawing, tag or weld number, and their result goes to the welds' visual inspection. For an NDE request you also choose the method and, to write results back to the welds when the report is approved, the result column and the test date. That column takes only Passed, Failed or blank (not tested), and a blank never stops the report being submitted;
  3. A column linked to WeldTrace is picked from the project: here the weld, then the WPS and the welder;
  4. A number column has a unit, printed with its heading;
  5. The lowest value accepted;
  6. The highest value accepted.

Step 6 - Add a calculated column

A calculated column

A calculated field or column works out its value from number fields, so nobody has to do the sum. Add a column, choose the type "Calculated" and give its unit.

  1. The formula, for example the maximum interpass temperature less the measured one. Use + - * / and brackets;
  2. Click a number field under "Use" to put it in the formula. In a table, a formula uses the columns of the same row;
  3. The number of decimals shown.

Step 7 - Show a section only when needed

A section shown only when needed

Click "Section of fields" to add a "Corrective action" section, with a long text field and a photos field.

  1. "Show" makes the section appear only when an earlier field has a given answer, here when All readings within limits is Fail. The rule can use a dropdown, pass or fail, accept or reject, checkbox or text field from another section;
  2. A photos field holds up to the number of photos you give, here four. The photos are added as image files while filling in the report, and print with it.

Use the arrows in a section's header to put the sections in order. Here the sign-off section, with a signature field for the welding inspector and one for the reviewer, comes last. Below the sections, "Signatures" adds the printed stamps and signatures of who prepared and who approved the report (see the article "Report Writer: adapt a starter template", Step 7).

Step 8 - Add fixed text and acceptance criteria

Acceptance criteria

Some text belongs on every report and is not filled in, for example the acceptance criteria or a note on the method.

  1. Choose the type "Acceptance criteria" to print the text highlighted, or "Fixed text" for a plain note;
  2. Type the text. It appears on the form and in the printed report as it is.

Step 9 - Try the form in the preview

The preview

The preview shows the form as it will be filled in. Try it before you submit: nothing in the preview is saved.

  1. Choose Fail for All readings within limits;
  2. The acceptance criteria are shown as fixed text;
  3. Type a few readings: the calculated margin works itself out;
  4. The Corrective action section appears, because a reading is out of limits.

Step 10 - Submit and approve

Approve the template

Click "Save", then "Submit for approval". A super user or account administrator then opens the template and clicks "Approve", or "Reject" with the reason.

  1. Add a comment if you like. It is kept in the approval history;
  2. Click "Approve".

Step 11 - The approved template

The approved template

The template is now in use in every project of the account. In a project, open "Test Reports", click "Report Writer", choose the template and click "New report" (see the article "Report Writer: adapt a starter template", Steps 11 to 15).

  1. The status is Approved. To change the template later, click "Revise": the new revision is approved in the same way, and reports already filled keep the revision they were made from;
  2. "History" shows who created, submitted and approved each revision, when, and their comments.

A project can also adapt an approved template for itself, for example to match a client's own form, with "Override for this project" on the project's Report Writer page (see the article "Report Writer").

Read the next article: "Report Writer".